COPEPODITE Incoming Data Review

Fatal Format Issues:   none



HEADER REVIEW SECTION
[
Jump back to TOP ]

SEQUENTIAL ORDERING OF ACTIVE DATA COLUMNS

    Column # 1     [ DATE-YMD ]       Date Set = 1
    Column # 2     [ABND= Total Zooplankton (#/five-nautical-miles)]      ( date set 1 )
    Column # 3     [TEMP= Temperature (C)]      ( date set 1 )
    Column # 4     [PSAL= Salinity ()]      ( date set 1 )
    Column # 5     [CHLA= Fluorescence ()]      ( date set 1 )


DATA SORTED BY CATEGORY TYPES

    Total/non-zero Abundance Category
        Column # 2   [ ABND= Total Zooplankton (#/five-nautical-miles) ]

    Temperatures Category
        Column # 3   [ TEMP= Temperature (C) ]

    Salinities Category
        Column # 4   [ PSAL= Salinity () ]




DATE REVIEW SECTION
[
Jump back to TOP ]

DATE COLUMNCommentsMinimum YearMaximum Year
DATES in Column 1 no problems detected 2008 2013

 Date Column LabelingDate Value-Set1Date Value-Set2Date Value-Set3
DATE-column Date-Label AutoDetect match? SET1min SET1max SET2min SET2max SET3min SET3max
1 DATE-YMD DATE-YMD yes 2008 2013 1 12 3 30



DATA REVIEW SECTION
[
Jump back to TOP ]



DATA COLUMN Comments"n" Minimum
(non-zero)
Maximum Values
> 0
Values
> 1
Column 2 :
[ 04_ABND= Total Zooplankton (#/five-nautical-miles) ]
no problems detected 373 1.00000000 3513.00000 370
( 99 %)
363
( 97 %)
Column 3 :
[05_TEMP= Temperature (C) ]
There is/are 3 count WARNING(S)!

All/most of your values are EMPTY (missing).
This variable will be ignored!


Possible warning triggers:
  • a non-numeric value was encountered!
  • text comments like "null" or "n/a" will be ignored.
  • Engineering units ("1.25E5", "1.25 x 10^5")

  • 0 9999999.00 -9999999.00 0
    ( -2147483648 %)
    0
    ( -2147483648 %)
    Column 4 :
    [06_PSAL= Salinity () ]
    There is/are 3 count WARNING(S)!

    All/most of your values are EMPTY (missing).
    This variable will be ignored!


    Possible warning triggers:
  • a non-numeric value was encountered!
  • text comments like "null" or "n/a" will be ignored.
  • Engineering units ("1.25E5", "1.25 x 10^5")

  • 0 9999999.00 -9999999.00 0
    ( -2147483648 %)
    0
    ( -2147483648 %)
    Column 5 :
    [07_CHLA= Fluorescence () ]
    There is/are 3 count WARNING(S)!

    All/most of your values are EMPTY (missing).
    This variable will be ignored!


    Possible warning triggers:
  • a non-numeric value was encountered!
  • text comments like "null" or "n/a" will be ignored.
  • Engineering units ("1.25E5", "1.25 x 10^5")

  • 0 9999999.00 -9999999.00 0
    ( -2147483648 %)
    0
    ( -2147483648 %)

    The "Values >0" and "Values >1" columns look for data cases in which data values are heavily counts of "zero" or "1".