COPEPODITE Incoming Data Review

Fatal Format Issues:   none



HEADER REVIEW SECTION
[
Jump back to TOP ]

SEQUENTIAL ORDERING OF ACTIVE DATA COLUMNS

    Column # 1     [ DATE-DMY ]       Date Set = 1
    Column # 2     [TEMP= Temperature (C) at the surface]      ( date set 1 )
    Column # 3     [PSAL= Salinity () at the surface]      ( date set 1 )
    Column # 4     [CHLA= Chlorophyll (ug/l) at the surface]      ( date set 1 )
    Column # 5     [OTHR= Secchi Depth (m)]      ( date set 1 )
    Column # 6     [OTHR= Oxygen (mg/l) at the surface]      ( date set 1 )
    Column # 7     [OTHR= pH () at the surface]      ( date set 1 )
    Column # 8     [LOTH= Turbidity (NTU) at the surface]      ( date set 1 )

    Column # 9     [ DATE-DMY ]       Date Set = 2
    Column # 10     [LOTH= NO3NO2-N (ug/l) at the surface]      ( date set 2 )
    Column # 11     [LOTH= Ammonium-N (ug/l) at the surface]      ( date set 2 )
    Column # 12     [LOTH= Phosphate-P (ug/l) at the surface]      ( date set 2 )
    Column # 13     [LOTH= Silicate-Si (ug/l) at the surface]      ( date set 2 )


DATA SORTED BY CATEGORY TYPES

    non-Log10 (linear) Miscellaenous Category
        Column # 5   [ OTHR= Secchi Depth (m) ]
        Column # 6   [ OTHR= Oxygen (mg/l) at the surface ]
        Column # 7   [ OTHR= pH () at the surface ]

    Temperatures Category
        Column # 2   [ TEMP= Temperature (C) at the surface ]

    Salinities Category
        Column # 3   [ PSAL= Salinity () at the surface ]




DATE REVIEW SECTION
[
Jump back to TOP ]

DATE COLUMNCommentsMinimum YearMaximum Year
DATES in Column 1 no problems detected 1985 2010
DATES in Column 9 no problems detected 1985 2010

 Date Column LabelingDate Value-Set1Date Value-Set2Date Value-Set3
DATE-column Date-Label AutoDetect match? SET1min SET1max SET2min SET2max SET3min SET3max
1 DATE-DMY DATE-DMY yes 01 31 Apr Sep 00 99
9 DATE-DMY DATE-DMY yes 01 31 Apr Sep 00 99



DATA REVIEW SECTION
[
Jump back to TOP ]



DATA COLUMN Comments"n" Minimum
(non-zero)
Maximum Values
> 0
Values
> 1
Column 2 :
[ 04_TEMP= Temperature (C) at the surface ]
no problems detected 678 2.76999998 31.2399998 678
( 100 %)
678
( 100 %)
Column 3 :
[ 05_PSAL= Salinity () at the surface ]
no problems detected 662 5.99999987E-02 22.0000000 660
( 99 %)
632
( 95 %)
Column 4 :
[ 06_CHLA= Chlorophyll (ug/l) at the surface ]
no problems detected 240 -0.899999976 112.199997 239
( 99 %)
238
( 99 %)
Column 5 :
[ 07_OTHR= Secchi Depth (m) ]
no problems detected 245 0.300000012 2.40000010 245
( 100 %)
116
( 47 %)
Column 6 :
[ 08_OTHR= Oxygen (mg/l) at the surface ]
no problems detected 676 2.06999993 17.7000008 676
( 100 %)
676
( 100 %)
Column 7 :
[ 09_OTHR= pH () at the surface ]
no problems detected 647 5.48999977 9.39999962 647
( 100 %)
647
( 100 %)
Column 8 :
[ 10_LOTH= Turbidity (NTU) at the surface ]
no problems detected 237 7.99999982E-02 34.7999992 237
( 100 %)
222
( 93 %)
Column 10 :
[ 11_LOTH= NO3NO2-N (ug/l) at the surface ]
no problems detected 296 0.259467006 614.473938 296
( 100 %)
293
( 98 %)
Column 11 :
[ 12_LOTH= Ammonium-N (ug/l) at the surface ]
no problems detected 473 0.259999990 393.739899 466
( 98 %)
464
( 98 %)
Column 12 :
[ 13_LOTH= Phosphate-P (ug/l) at the surface ]
no problems detected 451 0.100000001 295.000000 451
( 100 %)
418
( 92 %)
Column 13 :
[ 14_LOTH= Silicate-Si (ug/l) at the surface ]
no problems detected 264 8.05504036 129.300690 264
( 100 %)
264
( 100 %)

The "Values >0" and "Values >1" columns look for data cases in which data values are heavily counts of "zero" or "1".