COPEPODITE Incoming Data Review

Fatal Format Issues:   none



HEADER REVIEW SECTION
[
Jump back to TOP ]

SEQUENTIAL ORDERING OF ACTIVE DATA COLUMNS

    Column # 1     [ DATE-DMY ]       Date Set = 1
    Column # 2     [TEMP= Temperature (C) at the surface]      ( date set 1 )
    Column # 3     [PSAL= Salinity () at the surface]      ( date set 1 )
    Column # 4     [CHLA= Chlorophyll (ug/l) at the surface]      ( date set 1 )
    Column # 5     [OTHR= Secchi Depth (m)]      ( date set 1 )
    Column # 6     [OTHR= Oxygen (mg/l) at the surface]      ( date set 1 )
    Column # 7     [OTHR= pH () at the surface]      ( date set 1 )
    Column # 8     [LOTH= Turbidity (NTU) at the surface]      ( date set 1 )

    Column # 9     [ DATE-DMY ]       Date Set = 2
    Column # 10     [LOTH= NO3NO2-N (ug/l) at the surface]      ( date set 2 )
    Column # 11     [LOTH= Ammonium-N (ug/l) at the surface]      ( date set 2 )
    Column # 12     [LOTH= Phosphate-P (ug/l) at the surface]      ( date set 2 )
    Column # 13     [LOTH= Silicate-Si (ug/l) at the surface]      ( date set 2 )


DATA SORTED BY CATEGORY TYPES

    non-Log10 (linear) Miscellaenous Category
        Column # 5   [ OTHR= Secchi Depth (m) ]
        Column # 6   [ OTHR= Oxygen (mg/l) at the surface ]
        Column # 7   [ OTHR= pH () at the surface ]

    Temperatures Category
        Column # 2   [ TEMP= Temperature (C) at the surface ]

    Salinities Category
        Column # 3   [ PSAL= Salinity () at the surface ]




DATE REVIEW SECTION
[
Jump back to TOP ]

DATE COLUMNCommentsMinimum YearMaximum Year
DATES in Column 1 no problems detected 1996 2010
DATES in Column 9 no problems detected 1996 2010

 Date Column LabelingDate Value-Set1Date Value-Set2Date Value-Set3
DATE-column Date-Label AutoDetect match? SET1min SET1max SET2min SET2max SET3min SET3max
1 DATE-DMY DATE-DMY yes 01 31 Apr Sep 00 99
9 DATE-DMY DATE-DMY yes 01 31 Apr Sep 00 99



DATA REVIEW SECTION
[
Jump back to TOP ]



DATA COLUMN Comments"n" Minimum
(non-zero)
Maximum Values
> 0
Values
> 1
Column 2 :
[ 04_TEMP= Temperature (C) at the surface ]
no problems detected 555 0.241999999 32.0900002 555
( 100 %)
554
( 99 %)
Column 3 :
[ 05_PSAL= Salinity () at the surface ]
no problems detected 538 1.99999996E-02 15.2100000 506
( 94 %)
282
( 52 %)
Column 4 :
[ 06_CHLA= Chlorophyll (ug/l) at the surface ]
no problems detected 238 -1.39999998 215.500000 237
( 99 %)
235
( 98 %)
Column 5 :
[ 07_OTHR= Secchi Depth (m) ]
no problems detected 246 0.250000000 2.00000000 246
( 100 %)
55
( 22 %)
Column 6 :
[ 08_OTHR= Oxygen (mg/l) at the surface ]
no problems detected 555 7.99999982E-02 21.5699997 555
( 100 %)
553
( 99 %)
Column 7 :
[ 09_OTHR= pH () at the surface ]
no problems detected 553 5.90000010 9.30000019 553
( 100 %)
553
( 100 %)
Column 8 :
[ 10_LOTH= Turbidity (NTU) at the surface ]
no problems detected 236 0.200000003 37.2000008 236
( 100 %)
234
( 99 %)
Column 10 :
[ 11_LOTH= NO3NO2-N (ug/l) at the surface ]
no problems detected 308 1.13972998 1010.00000 308
( 100 %)
308
( 100 %)
Column 11 :
[ 12_LOTH= Ammonium-N (ug/l) at the surface ]
no problems detected 359 1.39999998 363.000000 359
( 100 %)
359
( 100 %)
Column 12 :
[ 13_LOTH= Phosphate-P (ug/l) at the surface ]
no problems detected 351 1.61456299 267.000000 350
( 99 %)
350
( 99 %)
Column 13 :
[ 14_LOTH= Silicate-Si (ug/l) at the surface ]
no problems detected 265 9.22999954 147.000000 265
( 100 %)
265
( 100 %)

The "Values >0" and "Values >1" columns look for data cases in which data values are heavily counts of "zero" or "1".